ControlActionsDone
(read/write)
This property sets/gets a flag for indicating that the control actions are done.
Example
% Create DSS object
DSSObject = actxserver('OpenDSSEngine.DSS')
if ~DSSObject.Start(0),
disp('Unable to start openDSS');
return
end;
DSSText = DSSObject.Text;
DSSCircuit = DSSObject.ActiveCircuit;
% Compile a model
DSSText.Command = 'Compile C:\myPath\myModel.dss';
DSSSolution = DSSCircuit.Solution;
% solves the circuit without control actions
DSSSolution.SolveNoControl();
% samples and executes control actions
DSSSolution.CheckControls();
% Executes status check in all fault objects
DSSSolution.CheckFaultStatus();
% Executes status check in all fault objects
DSSSolution.Cleanup();
% Checks if the control actions are done
if DSSSolution.ControlActionsDone,
mySolver = 'Control actions are done';
else
mySolver = 'No control actions executed';
end;