(read/write)


This property sets/gets the power factor (PF) for generators in AutoAdd mode.


Example


% Create DSS object

DSSObject = actxserver('OpenDSSEngine.DSS')

if ~DSSObject.Start(0),

                    disp('Unable to start openDSS');

                    return

end;

DSSText = DSSObject.Text;

DSSCircuit = DSSObject.ActiveCircuit;

% Compile a model        

DSSText.Command = 'Compile C:\myPath\myModel.dss';

DSSSolution = DSSCircuit.Solution;


% set the control iterations to 1000

DSSSolution.ControlIterations = 1000; 

% set simulation mode yearly

DSSSolution.Mode = 2;

% set simulation step size 1 h

DSSSolution.StepSize = 1;


% get the generator kW for AutoAdd mode

myGenkW = DSSSolution.GenkW;

% get the generator PF for AutoAdd mode

myGenPF = DSSSolution.GenPF;

% get the generator multiplier

myGenMult = DSSSolution.GenMult;