(read only)


This property returns the short circuit currents at the active bus. The values are returned as a complex Array.


Example


% Create DSS object

DSSObject = actxserver('OpenDSSEngine.DSS')

if ~DSSObject.Start(0),

                    disp('Unable to start openDSS');

                    return

end;

DSSText = DSSObject.Text;

DSSCircuit = DSSObject.ActiveCircuit;

% Compile a model        

DSSText.Command = 'Compile C:\myPath\myModel.dss';

DSSActiveBus = DSSCircuit.ActiveBus;

% Sets bus "myBus" as the active Bus

DSSCircuit.SetActiveBus('myBus')

myIsc = DSSActiveBus.Isc;

mySize = size(myIsc);

myIMagAng = [];

% Converts from complex to polar

for i = 1:2:(mySize(2) - 1),

                    myIMagAng = [myIMagAng;[abs(myIsc(i) + j*myIsc(i + 1)),angle(myIsc(i) + j*myIsc(i + 1))*180/pi]];

end;