ReclosersV (Variant) Interface
This interface can be used to read/write certain properties of the active DSS object. The structure of the interface is as follows:
void ReclosersV(int32_t Parameter, uintptr_t *Pointer, int32_t *Type, int32_t *Size);
In this version of the DLL the API requires 4 arguments Some of these arguments are informative while others provide data access through memory address. This avoids creating unnecessary copies of the same data across the system. The 4 arguments used in this API are:
- Parameter: Indicates the data array that wants to be accessed/written.
- Pointer: Is the pointer to the array structure.
- Type: Is the type of data contained in the structure, it can be one of: 0 - Boolean, 1- Integer (32 bit), 2- double (64 bit), 3- Complex, 4- String.
- Size: Is the size in Bytes of the structure, it only considers the elements inside the structure without the identifiers added by DSS. In the case of array of strings includes the null byte (0) between the elements of the array.
The return values depend on the given Parameter, which can be one of the following:
Parameter 0: Reclosers.AllNames
This parameter returns a pointer to an array of bytes containing the names of all the existing Reclosers in the project. Each string is separated by a NULL (0) character.
Parameter 1: Reclosers.RecloseIntervals
This parameter returns a pointer to an array of doubles with the reclose intervals (s) between shots set for the active recloser.