SensorsF (Float) Interface
This interface can be used to read/write certain properties of the active DSS object. The structure of the interface is as follows:
double SensorsF(int32_t Parameter, double Argument);
This interface returns a floating point number with the result of the query according to the value of the variable Parameter, which can be one of the following:
Parameter 0: Sensors.PctError read
This parameter gets the assumed percent error in the Sensor measurement. Default is 1.
Parameter 1: Sensors.PctError write
This parameter sets the assumed percent error in the Sensor measurement. Default is 1.
Parameter 2: Sensors.Weight read
This parameter gets the weighting factor for this sensor measurement with respect to the other sensors. Default is 1.
Parameter 3: Sensors.Weight write
This parameter sets the weighting factor for this sensor measurement with respect to the other sensors. Default is 1.
Parameter 4: Sensors.kVbase read
This parameter gets the voltage base for the sensor measurements. LL for 2 and 3 - phase sensors, LN for 1-phase sensors.
Parameter 5: Sensors.kVbase write
This parameter sets the voltage base for the sensor measurements. LL for 2 and 3 - phase sensors, LN for 1-phase sensors.