SolveNoControl
(method)
This method is similar to SolveSnap except no control actions are checked or executed.
Example
% Create DSS object
DSSObject = actxserver('OpenDSSEngine.DSS')
if ~DSSObject.Start(0),
disp('Unable to start openDSS');
return
end;
DSSText = DSSObject.Text;
DSSCircuit = DSSObject.ActiveCircuit;
% Compile a model
DSSText.Command = 'Compile C:\myPath\myModel.dss';
DSSSolution = DSSCircuit.Solution;
% Set load multiplier 1.1
DSSSolution.LoadMult = 1.1;
% Set max control iterations to 100
DSSSolution.LoadMult = 100;
% Set max solution iterations to 20
DSSSolution.MaxIterations = 20;
% set simulation mode daily
DSSSolution.Mode = 1;
% Set number to perform only 12 hours
DSSSolution.Number = 12;
% solves the circuit without control actions
DSSSolution.SolveNoControl();
% sample controls
DSSSolution.SampleControlDevices();
% Do control actions
DSSSolution.DoControlActions();