TEnergyMeter
|
TEnergyMeter |
||
|
Type-access |
Command |
Description |
|
Implements the following properties/methods as in TMeterClass and 3.1.4:
|
||
|
Method-private |
ProcessOptions |
Parses the options for the energy meter. |
|
Method-private |
Set_SaveDemandInterval |
Sets the demand interval flag using the given value. |
|
Method-private |
Get_SaveDemandInterval |
Gets the demand interval flag. |
|
Method-private |
CreateMeterTotals |
Allocates in memory for the meter totals registers. |
|
Method-private |
CreateFDI_Totals |
Allocates in memory for the FDI totals registers. |
|
Method-private |
ClearDI_Totals |
Clears the DI totals registers. |
|
Method-private |
WriteTotalsFile |
Sum up all registers of all meters and write to Totals.CSV. |
|
Method-private |
OpenOverloadReportFile |
Allocates memory for the overload report, initializes the memory space with headers. |
|
Method-private |
OpenVoltageReportFile |
Allocates memory for the voltage violations report, initializes the memory space with headers. |
|
Method-private |
WriteOverloadReport |
Scans the active circuit for overloaded PD elements and writes each to a file. This is called only if in Demand Interval (DI) mode and the file is open. |
|
Method-private |
WriteVoltageReport |
For any bus with a defined voltage base, test for > Vmax or < Vmin and writes each to a file. This is called only if in Demand Interval (DI) mode and the file is open. |
|
Method-private |
InterpretRegisterMaskArray |
Interprets the registry mask array using the given reference. |
|
Method-private |
Set_DI_Verbose |
Sets the DI verbose flag. |
|
Method-private |
Get_DI_Verbose |
Gets the DI verbose flag. |
|
Method-protected |
SetHasMeterFlag |
Set the HasMeter Flag for all cktElement. |
|
Method-public |
ResetMeterZonesAll |
Force all EnergyMeters in the circuit to reset their meter zones. |
|
Method-public |
ResetAll |
Reset all meters in active circuit to zero. Overrides the more generic class. |
|
Method-public |
SampleAll |
Forces all meters in active circuit to sample. Overrides the more generic class. |
|
Method-public |
SaveAll |
Forces all meters in the circuit to take a sample. Overrides the more generic class. |
|
Method-public |
AppendAllDIFiles |
Appends the DI files for all the energy meters. |
|
Method-public |
OpenAllDIFiles |
Opens the DI files for all the energy meters. |
|
Method-public |
CloseAllDIFiles |
Closes the DI files for all the energy meters. |
|
Property-public |
SaveDemandInterval |
PA Get_SaveDemandInterval and Set_SaveDemandInterval. |
|
Property-public |
DI_Verbose |
PA Get_DI_Verbose and Set_DI_Verbose. |