TIndMach012Obj
|
TIndMach012Obj |
||
|
Type-access |
Command |
Description – (Specific class) otherwise generic |
|
Implements the following properties/methods as in TLoadObj:
|
||
|
Method- private |
InterpretOption |
Interprets the option for slip option. |
|
Method - private |
set_Localslip |
Sets the slip locally using the slip option set by the user. |
|
Method - private |
Get_PFlowModelCurrent |
Gets the power flow model current. |
|
Method - private |
Get_DynamicModelCurrent |
Uploads the injection currents for dynamics simulation mode. |
|
Method - private |
Set_Slip |
Sets the motor slip value. |
|
Property - private |
GetRotorLosses |
Returns the rotor losses. |
|
Property - private |
GetStatorLosses |
Returns the stator losses. |
|
Property - private |
Compute_dSdP |
Calculates and returns the dSdP based on rated slip and rated voltage. |
|
Method - private |
Randomize |
Implements the typical process for handling randomization in DSS fashion. |
|
Method - private |
InitModel |
Implements the routine for initializing the state variables and local variables of the model. |
|
Method - private |
CalcIndMach012ModelContribution |
Calculates the current injections for the model. |
|
Method - private |
DoIndMach012Model |
Computes the total terminal current for the model. |
|
Method - private |
CalcModel |
Given the present voltages returns currents in accordance to the simulation mode. |
|
Method - private |
InitTraceFile |
Initializes file for debugging purposes. |
|
Method - private |
WriteTraceRecord |
Adds a new line to the trace file. |
|
Property - private |
Get_PresentkV |
Gets the present voltage base at the model terminals. |
|
Method - private |
Set_PresentkV |
Sets the present voltage base at the model terminals. |
|
Method - private |
SetPowerkW |
Sets the kW base for the model. |
|
Method - protected |
Set_ConductorClosed |
Overrides the more generic class implementation to open/close model’s conductors. |
|
Method - protected |
DoDynamicMode |
Implements the routine for calculating the injection currents for the model in dynamics simulation mode. |
|
Method - public |
Integrate |
Implements the procedure for integrating the state variables of the model in dynamics simulation mode. |
|
Method - public |
CalcDynamic |
Provides the structure for calculating the dynamic injection currents for the model. |
|
Method - public |
CalcPFlow |
Calculates the power flow for the model using the local symmetric components. |
|
Method - public |
SetNominalPower |
Sets the power output for the model. |
|
Property - public |
NumVariables |
Overrides the more generic class implementation, returns the number of state variables in this model. |
|
Method - public |
GetAllVariables |
Overrides the more generic class implementation, uploads the values for the state variables in this model into the given pointer. |
|
Property - public |
Get_Variable |
Overrides the more generic class implementation, returns the value for the state variable pointed by given index. |
|
Method - public |
Set_Variable |
Overrides the more generic class implementation, sets the value for the state variable pointed by given index. |
|
Property - public |
VariableName |
Overrides the more generic class implementation, returns name of the state variable pointed by given index. |
|
Method - public |
InitStateVars |
Overrides the more generic class implementation, initializes the state variables. |
|
Method - public |
IntegrateStates |
Overrides the more generic class implementation, solves, and integrates the differential equation describing the model dynamics. |
|
Property - public |
LocalSlip |
PA S! (variable) and set_Localslip. |
|
Property - public |
Slip |
PA Set_Slip. |
|
Property - public |
PresentkV |
PA Get_PresentkV and Set_PresentkV. |