TLineObj
|
TLineObj |
||
|
Type-access |
Command |
Description |
|
Method-private |
FMakeZFromGeometry |
Make new Z, Zinv, Yc, etc. from line geometry reference. |
|
Method-private |
KillGeometrySpecified |
Indicate No Line Geometry specification if this is called. |
|
Method-private |
FMakeZFromSpacing |
make new Z, Zinv, Yc, etc. from linespacing reference. |
|
Method-private |
KillSpacingSpecified |
Indicate No Line spacing specification if this is called. |
|
Method-private |
ClearYPrim |
Clears the Y primitive memory spaces. |
|
Method-private |
ResetLengthUnits |
Resets the length units to the default. |
|
Method-private |
UpdatePDProperties |
Updates inherited properties. |
|
Property-private |
NumConductorData |
Defines the number of conductors for the element. |
|
Property-private |
FetchConductorData |
Gets the conductor data from the conductor data reference. |
|
Method-private |
ReallocZandYcMatrices |
Reallocate Z and Y matrices in memory (possible expansion). |
|
Method-private |
DoLongLine |
Long Line Correction for 1=phase. |
|
Method-private |
ConvertZinvToPosSeqR |
For GIC analysis, primarily. Uses only real part of Z. |
|
Method-public |
GetLosses |
Overrides the more specific class specification. Calculates the losses for the area. |
|
Method-public |
GetSeqLosses |
Overrides the more specific class specification. Calculates the losses for the area using sequential components. |
|
Method-public |
RecalcElementData |
See 3.1.9. |
|
Method-public |
CalcYPrim |
See 3.1.9. |
|
Method-public |
MakePosSequence |
See 3.1.9. |
|
Property-public |
MergeWith |
Merge this line with another line and disable the other line. |
|
Method-public |
UpdateControlElements |
Updates the elements controlled/assigned to the controllers in the model. |
|
Property-public |
GetPropertyValue |
See 3.1.9. |
|
Method-public |
InitPropertyValues |
See 3.1.9. |
|
Method-public |
DumpProperties |
See 3.1.9. |
|
Method-public |
FetchLineCode |
Loads the line code given in the argument into the active line. |
|
Method-public |
FetchGeometryCode |
Loads the line geometry given in the argument into the active line. |
|
Method-public |
FetchLineSpacing |
Loads the line spacing given in the argument into the active line. |
|
Method-public |
FetchWireList |
Loads the wire data given in the argument into the active line. |
|
Method-public |
FetchCNCableList |
Loads the CNCable data given in the argument into the active line. |
|
Method-public |
FetchTSCableList |
Loads the TSCable data given in the argument into the active line. |
|
Method-public |
CalcFltRate |
Overrides the generic class declaration. Calculates failure rates for section and buses. |