TPCElement
|
TPCElement |
||
|
Type-access |
Command |
Description – (Specific class) otherwise generic |
|
Method- private |
GetTerminalCurrents |
Returns the currents at the active terminal |
|
Property- private |
Get_Variable |
Returns the numeric value (double) of the state variable indicated in the argument by index. |
|
Method- private |
Set_Variable |
Sets the numeric value (double) of the state variable indicated in the argument by index. |
|
Method- public |
ZeroInjCurrent |
Sets the local injection currents array to zero. |
|
Method- public |
InitPropertyValues |
Initializes the local property array with the default values. |
|
Method- public |
GetCurrents |
Gets the present current values at the active terminal. |
|
Method- public |
GetInjCurrents |
Gets the injection currents array at the active terminal. |
|
Method- public |
ComputeIterminal |
Overrides the generic class call to define the local procedure for computing the current at the element’s terminal. |
|
Property- public |
InjCurrents |
Overrides the generic class call to define the local procedure for adding the local injection currents into System currents array. |
|
Method- public |
CalcYPrimContribution |
Calculates the Yprim contribution to the injection currents array using the present values. |
|
Method- public |
DumpProperties |
Implements the routine for writing the local properties down into a plain text file at the end. |
|
Method- public |
InitHarmonics |
Initializes the variables of the calling object for harmonics simulation mode. |
|
Method- public |
set_ITerminalUpdated |
Sets the ITerminalUpdated flag using the value given in the argument. |
|
Method- public |
InitStateVars |
Sets the foundation for initializing the state variables of the calling object. It is expected to be override by a more specific class. If not overridden, when called it does nothing. |
|
Method- public |
IntegrateStates |
Sets the foundation for defining the procedure to integrate the state variables of the calling object. It is expected to be override by a more specific class. If not overridden, when called it does nothing. |
|
Property- public |
NumVariables |
Sets the foundation for defining the number of state variables of the calling object. It is expected to be override by a more specific class. If not overridden, when called it does nothing. |
|
Method- public |
GetAllVariables |
Sets the foundation for returning the values for all the state variables of the calling object. It is expected to be override by a more specific class. If not overridden, when called it does nothing. |
|
Property- public |
VariableName |
Sets the foundation for returning the value the state variable indicated in the argument by index. It is expected to be override by a more specific class. If not overridden, when called it does nothing. |
|
Property- public |
LookupVariable |
Search through variable name list and return index if found. Otherwise, returns -1. |
|
Property- public |
Property- public |
PA Get_Variable and Set_Variable. |