TStorageControllerObj
|
TStorageControllerObj |
||
|
Type-access |
Command |
Description |
|
Implements the following properties/methods as in TCapControlObj, TStorageObj and TExpControlObj:
|
||
|
Method-private |
SetAllFleetValues |
Sets the dispatch values for all the storage devices in the fleet. |
|
Method-private |
SetFleetkWRate |
Sets the kW values for all the storage devices in the fleet. |
|
Method-private |
SetFleetChargeRate |
Sets the charging rate for all the storage devices in the fleet. |
|
Method-private |
SetFleetToCharge |
Commands the fleet to enter in charging mode. |
|
Method-private |
SetFleetToDisCharge |
Commands the fleet to enter in discharging mode. |
|
Method-private |
SetFleetToIdle |
Commands the fleet to enter in Idle mode. |
|
Method-private |
SetFleetToExternal |
Commands the fleet to enter in external mode. |
|
Method-private |
SetFleetDesiredState |
Commands the fleet to enter in desired mode. |
|
Property-private |
InterpretMode |
Interprets the mode embedded in the given string. |
|
Property-private |
GetModeString |
Returns the present mode for the fleet. |
|
Property-private |
GetkWTotal |
Returns the total kW. |
|
Property-private |
GetkWhTotal |
Returns the total kWh. |
|
Property-private |
GetkWhActual |
Returns the present kWh. |
|
Property-private |
GetkWActual |
Returns the present kW. |
|
Property-private |
GetkWActual |
Returns the present kW. |
|
Property-private |
ReturnSeasonTarget |
Returns the seasonal target. |
|
Property-private |
ReturnElementsList |
Returns the list of controlled elements as string. |
|
Property-private |
ReturnWeightsList |
Returns the weigh list as string. |
|
Property-private |
MakeFleetList |
Allocates the list of storage devices controlled by this control. |
|
Method-private |
DoLoadFollowMode |
Implements the control routine for follow control mode. |
|
Method-private |
DoLoadShapeMode |
Implements the control routine for load shape control mode. |
|
Method-private |
DoTimeMode |
Implements the control routine for time control mode. |
|
Method-private |
DoScheduleMode |
Implements the control routine for schedule control mode. |
|
Method-private |
DoPeakShaveModeLow |
Implements the control routine for peak shave control mode. |
|
Method-private |
PushTimeOntoControlQueue |
Push present time onto control queue to force re solve at new dispatch value. |
|
Property-private |
NormalizeToTOD |
Normalize time to a floating-point number representing time of day If Hour > 24 time should be 0 to 23.999999. |
|
Property-private |
GetControlPower |
Returns the total power of the fleet. |
|
Property-private |
GetControlCurrent |
Returns the control current. |
|
Property-private |
Get_FleetkW |
Returns the fleet kW. |
|
Property-private |
Get_FleetkWh |
Returns the fleet kWh. |
|
Property-private |
Get_FleetkWhRating |
Returns the fleet kWh rating. |
|
Property-private |
Get_FleetReservekWh |
Returns the fleet kWh reserve. |
|
Property-private |
Get_DynamicTarget |
Returns the target considering the seasonal ratings. |
|
Property-public |
FleetkW |
PA Get_FleetkW. |
|
Property-public |
FleetkWh |
PA Get_FleetkWh. |
|
Property-public |
FleetkWhRating |
PA Get_FleetkWhRating. |
|
Property-public |
FleetReservekWh |
PA Get_FleetReservekWh. |