(read/write)


This property sets/gets the Factor to scale Y values from original curve.


Example


% Create DSS object

DSSObject = actxserver('OpenDSSEngine.DSS')

if ~DSSObject.Start(0),

                    disp('Unable to start openDSS');

                    return

end;

DSSText = DSSObject.Text;

DSSCircuit = DSSObject.ActiveCircuit;

% Compile a model        

DSSText.Command = 'Compile C:\myPath\myModel.dss';

DSSXY = DSSCircuit.XYCurves;

% activate the first XY curve of the list

i = DSSXY.First;

% define new XYCurve

DSSText.Command = 'New XYCurve.SmartInv0 npts=7 xarray=[0.4 0.86 1 1 1 1.14 1.6] yarray=[1 1 0 0 0 -1 -1]';

% set value X in 1.13

DSSXY.x = 1.13;

% get the Y value corresponding to X

myY = DSSXY.y;

% get the Y values

myYValues = DSSXY.Yarray;

% get the factor to scale y

myYScaleF = DSSXY.Yscale;

% get Y shift

myYShift = DSSXY.Yshift;