This interface can be used to read/write certain properties of the active DSS object. The structure of the interface is as follows:


CStr CapControlsS(int32_t Parameter, CStr Argument);


This interface returns a string with the result of the query according to the value of the variable Parameter, which can be one of the following:


Parameter 0: CapControls.Name read

This parameter gets the name of the active CapControl.


Parameter 1: CapControls.Name write

This parameter sets a CapControl active by name.


Parameter 2: CapControls.Capacitor read

This parameter gets the name of the capacitor that is controlled.


Parameter 3: CapControls.Capacitor write

This parameter sets the name of the capacitor that is controlled.


Parameter 4: CapControls.MonitoredObj read

This parameter gets the full name of the element that PT and CT are connected to.


Parameter 5: CapControls.MonitoredObj write

This parameter sets the full name of the element that PT and CT are connected to.